| Series surplus electric current chopper of TL1L |
| |
|
Model |
TL1L-100 |
TL1L-225 |
TL1L-400 |
TL1L-630.800 |
Maximum hull rack order rated current |
100 |
225 |
400 |
800 |
Rated current |
10 16 20 25 32 |
100 125 140 160 |
255 315 |
400 500 630 |
40 50 63 80 100 |
180 200 225 |
350 400 |
700 800 |
Poled number |
3 |
4 |
3 |
4 |
3 |
4 |
3 |
4 |
Rated insulation voltage |
|
AC800 |
|
|
Rated voltage |
|
AC400 |
|
|
Rated impact endures voltage |
8000 |
8000 |
8000 |
8000 |
Arc over distance |
50 |
50 |
100 |
100 |
Disjunction capacity rank |
L |
M |
H |
L |
M |
H |
L |
M |
H |
L |
M |
H |
Rating short disjunction capacity |
AC400V |
35 |
50 |
85 |
35 |
50 |
85 |
50 |
70 |
100 |
50 |
70 |
100 |
Moving short disjunction capacity |
AC400V |
22 |
35 |
50 |
22 |
35 |
50 |
30 |
40 |
50 |
30 |
40 |
50 |
Rating surplus short disjunction capacity |
8.75 |
12.5 |
21 |
8.75 |
12.5 |
21 |
12.5 |
17.5 |
25 |
12.5 |
17.5 |
25 |
Rated Surplus move current |
Non- time delay |
30/100/500 |
100/300/500 |
100/300/500 |
300/500/1000 |
Time delay |
100/300/500 |
100/300/500 |
100/300/500 |
300/500/1000 |
Rated Surplus no move current |
1/2l/En |
1/2l/En |
1/2l/En |
1/2l/En |
Operation
performance |
Electrify |
1500 |
1000 |
1000 |
1000 |
No |
8500 |
7000 |
4000 |
4000 |
Total |
10000 |
8000 |
5000 |
5000 |
Surplus protect move time |
l/En |
2l/En |
5l/En |
10l/En |
Maximum disjunction time |
Non- time delay |
0.2 |
0.1 |
0.04 |
0.04 |
Time delay |
0.5/1.15/2.15 |
0.35/1/2 |
0.25/0.9/1.9 |
0.25/0.9/1.9 |
|
|
The CDM1L series surplus electric current chopper( call the chopper as follows), mainly be applicable to communicate 50 Hzs, the sum settles the electric voltage 400 Vs, the sum settles the electric current to the 800 As to go together with to give or get an electric shock in the network, using to provide indirect contact protection to the person, also can use to keep causable fire from is dangerous because the equipments insulates the damage, produce to connect a ground of breakdown electric current, and can use to assign the electric power and the protection circuit and the power supply equipments of over carry and short circuit, can also be the circuit not multifarious conversion and electric motors not multifarious start it with.The normal regulations take the mold a work of the electric leakage protection the power supply sampling that the surplus electric current protects the chopper is two mutually, this series chopper is three mutually, if lack an any mutually, the chopper electric leakage protection the mold piece is still ability normal work;The sum settles the surplus action electric current I and biggest break to open time is adjustable according to the actual circumstance on the scene;When mutually the electric voltage lowers to the 50 Vs, electric leakage protection the mold piece is still ability normal work;Have the electric leakage reports to the police the exportation function.
|
|
|
| |
|
|